4.6 Article Proceedings Paper

Perceived and actual performance of daily tasks: Relationship to visual function tests in individuals with retinitis pigmentosa

期刊

OPHTHALMOLOGY
卷 108, 期 1, 页码 65-75

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/S0161-6420(00)00413-9

关键词

-

资金

  1. NEI NIH HHS [P30 EY001792, EY01792, EY08301, R01 EY008301] Funding Source: Medline
  2. NATIONAL EYE INSTITUTE [R01EY008301, P30EY001792] Funding Source: NIH RePORTER

向作者/读者索取更多资源

Purpose: To investigate the functioning in daily task performance of individuals with retinitis pigmentosa (RP), Goals were (1) to quantify the relationships among clinical tests of vision, seif-reports, and evaluations of actual task performance to predict difficulty in these tasks; and (2) to validate self-report questionnaire data about daily task performance with observations and measurements of actual task performance conducted by a certified low-vision specialist. Design: A cross-sectional study and survey. Participants: Sixty-two individuals with RP (mean age, 37 years) participated in the study. Methods: We obtained data about task performance from subjects' reports about their daily performance as assessed by a 53-item questionnaire and from a specialist's rating about actual ability on a 64-item battery of tasks, including ones similar to those assessed with the questionnaire. Main Outcome Measures: Clinical measures of vision included visual acuity, visual fields using Goldmann perimetry, letter contrast sensitivity, and cone and rod electroretinogram (ERG) function. The questionnaire and functional tasks were clustered into three categories: reading, mobility, and peripheral detection. Results: Self-report was correlated significantly with actual task performance. Task performance was correlated significantly with clinical test performance. Moderate or worse difficulty in performance was observed only for visual acuity worse than 20/40; log contrast sensitivity less than 1.4, a visual field area smaller than 2000 deg(2) (area equivalent to a 50-degree diameter of visual field to the Goldmann II-4-e target); and ERG amplitudes less than 10 microvolts for 32-Hz light-adapted white flicker. Conclusions: Despite the significant correlations, there remains variability in task performance that is unaccounted for in some individuals with low levels of clinical test performance. The assessment of actual task performance validated the use of self-reports in individuals with RP. Ophthalmology 2001;108:65-75 (C) 2001 by the American Academy of Ophthalmology.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据