3.8 Article

UV disinfection of soluble oil metalworking fluids

期刊

AIHAJ
卷 63, 期 2, 页码 178-183

出版社

AMER INDUSTRIAL HYGIENE ASSOC
DOI: 10.1080/15428110208984702

关键词

disinfection; metalworking fluids; Pseudomonas fluorescens; ultraviolet

向作者/读者索取更多资源

The efficacy of a new high-intensity germicidal ultraviolet (UV) lamp for disinfection of opaque metalworking fluids (MWF) was investigated under laboratory conditions. Three dilutions of soluble oil MWF and water controls in a circulating system were inoculated with suspensions of Pseudomonas fluorescens to an initial concentration of about 10(7) colony forming units (CFU) per milliliter and irradiated with a submerged nonglass UV lamp. Aliquots of the circulating fluid were withdrawn before irradiation and at 10-sec intervals in the water control and 10-min intervals in the MWF The samples were diluted with sterile water, plated, and counted after 18-24 hours' incubation. The UV-C radiation output of the lamp was estimated by irradiance measurements using a research radiometer. The concentration of CFU decreased by at least 2 logs (>99% reduction in culturability) in 30 sec in irradiated water, In all three dilutions of MWF, a 2-log decrease was obtained within 60 min. The UV-C output of the lamp was estimated at about 6 W. The disinfection appeared to follow a first order rate law both in MWF and in water. The CFU concentration was stable over time in unirradiated controls. These results demonstrate that UV disinfection is feasible in MWF opaque to both visible and UV wavelengths of light.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据