4.7 Article Proceedings Paper

Examples of reinforcement corrosion monitoring by embedded sensors in concrete structures

期刊

CEMENT & CONCRETE COMPOSITES
卷 31, 期 8, 页码 545-554

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.cemconcomp.2009.05.007

关键词

Electrochemical techniques; Linear polarization; Corrosion rate; Service life

向作者/读者索取更多资源

An increasing number of concrete structures are being monitored to enhance their durability. However, the literature provides only some guidance for the interpretation of the monitoring results [Broomfield JP. Corrosion of steel in concrete, understanding investigation and repair. 2nd ed. UK: Taylor & Francis; 2006; Andrade C, Alonso C. On-site measurements of corrosion rate of reinforcements. Constr Build Mater 2001;15(2-3):141-45; EN 206 2000. Concrete-Part 1: specification, performance, production and conformity]. Past experience shows the difficulty of interpreting the data collected due to the influence of temperature and moisture, and of using these data to predict future evolution of any deterioration processes. This paper presents several examples of recorded data for corrosion potential, electrical resistance and corrosion rates, along with a methodology to obtain a representative corrosion rate, averaged per year. The representative value can be used in corrosion predictive models to calculate the remaining service life. (C) 2009 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据