Late-stage occlusions of peripheral synthetic bypass grafts are frequently due to intimal hyperplasia and/or thrombosis at the distal anastomosis, resulting in unacceptably high failure rates. It has been widely established that hemodynamic and blood particle interactions with the vascular surface as well as surgical injury and compliance mismatch are inciting mechanisms capable of eliciting various cellular level responses associated with distal anastomotic intimal hyperplasia (IH) formation. Primary geometric factors influencing anastomotic hemodynamics include the graft-to-artery diameter ratio and graft-hood shape, which are determined by the graft caliber and initial graft-end cut selected by the vascular surgeon. In this study, the particle-hemodynamic effects of graft-end cuts (straight, curved, and S-shaped) and graft-to-artery diameter ratios (2:1 vs. 1.5:1) have been numerically assessed in four common unexpanded anastomotic configurations with respect to vortical flow patterns, wall shear stress based parameters, and platelet interactions with the vascular surface. Sites of significant platelet-wall interactions have been identified by a novel nearwall residence time (NWRT) model, which includes shear stress based factors for platelet activation and endothelial cell expression of anti-thrombogenic compounds. Of the configurations evaluated, straight and curved graft-end cuts with a graft-to-artery diameter ratio of 1.5:1 were found to reduce the particle-hemodynamic potential for IH development at locations critical to flow delivery. Nevertheless, the potential for significant IH occurrence via platelet and/or endothelial response pathways was highly evident in all conventional anastomoses considered, such that a decisively superior configuration was not determined. These results illustrate the need for alternative anastomotic designs with the intent of reducing critical hemodynamic wall parameters and mitigating regions of significant particle-wall interactions. (C) 2003 IPEM. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据