4.5 Article

The impact of myocardial flow reserve on the detection of coronary artery disease by perfusion Imaging methods: An NHLBI WISE Study

期刊

出版社

MARCEL DEKKER INC
DOI: 10.1081/JCMR-120022263

关键词

magnetic resonance; myocardium; perfusion; coronary artery disease; radionuclide; SPECT

资金

  1. DIVISION OF HEART AND VASCULAR DISEASES [N01HV068163, N01HV068164, N01HV068161] Funding Source: NIH RePORTER
  2. NATIONAL CENTER FOR RESEARCH RESOURCES [M01RR000425] Funding Source: NIH RePORTER
  3. NCRR NIH HHS [MO1-RR00425] Funding Source: Medline
  4. NHLBI NIH HHS [N01-HV-68161, N01-HV-68164, N01-HV-68163] Funding Source: Medline

向作者/读者索取更多资源

Myocardial flow reserve (MFR) is not routinely assessed in myocardial perfusion imaging (MPI) studies but has been hypothesized to affect test accuracy when assessing disease severity by coronary vessel lumenography. Magnetic resonance imaging (MRI) is an emerging diagnostic technique that can both perform MPI and assess MFR. We studied women (n = 184) enrolled in the Women's Ischemia Syndrome Evaluation (WISE) study with symptoms suggesting ischemic heart disease. Tests performed were coronary angiography and MPI by both MR and gated radionuclide single photon emission computed tomography (gated-SPECT). The MFR index was calculated using the MR data acquired at baseline and under vasodilation (dipyridamole) conditions. The study was structured with a pilot and an implementation phase. During the pilot phase (n = 46) data were unmasked and an MFR threshold was defined to divide patients into those with an adequate (A(MFRI)) or inadequate (IMFRI) MFR index. During the implementation phase, the MFR index threshold was prospectively applied to patients (n = 138). In the implementation phase, MPI ischemia detection accuracy compared to severe (greater than or equal to70%) coronary artery diameter narrowing by angiography was higher in the A(MFRI) vs. the I-MFRI group for MRI (86% vs. 70%, p < 0.05) and gated-SPECT (89% vs. 67%, p < 0.01). The I-MFRI group (n = 55 30% of study population) had a higher resting rate-pressure product compared with the AMFRI group (10,599 +/- 2871 vs. 9378 +/- 2447 bpm mmHg, p < 0.01), consistent with higher resting myocardial flow. When compared with each other, MRI and gated-SPECT MPI showed no difference in accuracy among MFR groups. Myocardial perfusion patterns in the IMFRI group may have resulted in atypical perfusion patterns, which either masked or mimicked epicardial coronary artery disease.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据