4.0 Article

The application of HPLC-F and GC-MS to the analysis of selected hydroxy polycyclic hydrocarbons in two certified fish bile reference materials

期刊

JOURNAL OF ENVIRONMENTAL MONITORING
卷 5, 期 3, 页码 513-520

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/b300903n

关键词

-

向作者/读者索取更多资源

Four selected hydroxy polycyclic aromatic hydrocarbons (OH-PAHs), 2-hydroxy-naphthalene (2-OH-NPH), 1-hydroxy-phenanthrene (1-OH-PHE), 1-hydroxy-pyrene (1-OH-PYR) and 3-hydroxy-benzo[a] pyrene (3-OH-BaP) have been analysed in two certified fish bile reference materials (CRMs) for exposure monitoring of PAHs in the aquatic environment. The two materials, BCR 720 and BCR 721, consist of bile from fish exposed to contaminated sediment and dispersed crude oil, respectively. Both bile samples have been analysed by two different analytical techniques, gas chromatography-mass spectrometry (GC-MS) and high performance liquid chromatography- fluorescence detection (HPLC-F), and the separation performance, detection limits, recoveries and reproducibility for the four target compounds were evaluated. HPLC-F requires a simple sample preparation and the separation capacity is adequate for quantification of 1-OH-PYR and 3-OH-BaP. Detection limits are excellent for 1-OH-PYR ( 6 pg injected) and 3-OH-BaP ( 3 pg injected) and generally improved with increasing molecular size. Recoveries ranged from 48 to 99% for the four selected compounds, depending on compound and concentration. Sample preparation prior to GC-MS analysis was more demanding, as reflected by the obtained recoveries for 2-OH-NPH, 1-OH-PHE and 1-OH-PYR ( 35 to 61%). The sensitivity improved with decreasing molecular size, 2-OH-NPH (1.2 pg injected), 1-OH-PHE (2.4 pg injected) and 1-OH-PYR ( 6 pg injected). Because of the superior separation power of GC and the extra selectivity of MS detection, GC-MS was the method of choice for the determination of 2-OH-NPH and 1-OH-PHE in both CRMs. In fish bile samples these two compounds are more likely to suffer from chromatographic overlap, and HPLC-F was not sufficiently selective. Determination of 1-OH-PYR was performed with success by both methods, but HPLC-F would be preferred because of the simpler and less time-consuming sample preparation. Detectable concentrations of 3-OH-BaP were present in BCR 720 and could only be determined by HPLC-F. The present work aims to present HPLC-F and GC-MS as complementary methods for the quantitative analysis of OH-PAHs in fish bile.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.0
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据