4.7 Article

MR tagging of human lungs using hyperpolarized He-3 gas

期刊

JOURNAL OF MAGNETIC RESONANCE IMAGING
卷 17, 期 1, 页码 142-146

出版社

JOHN WILEY & SONS INC
DOI: 10.1002/jmri.10226

关键词

hyperpolarized He-3; tagging; lungs; diffusion; ventilation

向作者/读者索取更多资源

Purpose: To evaluate the use of spin-tagging in conjunction with hyperpolarized gas imaging for monitoring lung 1 ventilation and gas diffusion. Methods and Materials: Images were taken at 0.15 T using single shot RARE, with hyperpolarized He-3 gas prepared by the metastability exchange technique. Sinusoidal modulation of the longitudinal magnetization (tag) was produced by two 90-degree rf pulses separated by a gradient pulse. The diffusion of He-3 gas in the lungs was measured by monitoring the decay of the tags. This study was conducted on a 25-year-old, male, healthy volunteer. Results: Clear tags in hyperpolarized He-3 gas both in vivo and in vitro were generated. The relative movement of the lung compared to a static, partial breath-hold was measured following inspiration or expiration. The diffusion coefficient of 3 He in the lungs was found to be 0.02 +/- 0.005 cm(2) seconds(-1). Conclusion: The spin-tagging of hyperpolarized He-3 in the lungs is possible, and allows regional lung movements to be measured following inspiration and expiration. It also allows quantification of the diffusion of the He-3 gas.