4.0 Article

Reproducibility of Transcranial Doppler ultrasound in the middle cerebral artery

期刊

CARDIOVASCULAR ULTRASOUND
卷 16, 期 -, 页码 -

出版社

BMC
DOI: 10.1186/s12947-018-0133-z

关键词

Transcranial Doppler; Microembolic signals; Carotid artery stenosis; Ischaemic stroke

资金

  1. Princess Margaret Research Development Fellowship
  2. MRC [G0701127] Funding Source: UKRI

向作者/读者索取更多资源

Background: Transcranial Doppler ultrasound remains the only imaging modality that is capable of real-time measurements of blood flow velocity and microembolic signals in the cerebral circulation. We here assessed the repeatability and reproducibility of transcranial Doppler ultrasound in healthy volunteers and patients with symptomatic carotid artery stenosis. Methods: Between March and August 2017, we recruited 20 healthy volunteers and 20 patients with symptomatic carotid artery stenosis. In a quiet temperature-controlled room, two 1-h transcranial Doppler measurements of blood flow velocities and microembolic signals were performed sequentially on the same day (within-day repeatability) and a third 7-14 days later (between-day reproducibility). Levels of agreement were assessed by interclass correlation co-efficient. Results: In healthy volunteers (31 +/- 9 years, 11 male), within-day repeatability of Doppler measurements were 0.880 (95% CI 0.726-0.950) for peak velocity, 0.867 (95% CI 0.700-0.945) for mean velocity, and 0.887 (95% CI 0.741-0.953) for end-diastolic velocity. Between-day reproducibility was similar but lower: 0.777 (95% CI 0.526-0.905), 0.795 (95% CI 0. 558-0.913), and 0.674 (95% CI 0.349-0.856) respectively. In patients (72 +/- 11 years, 11 male), within-day repeatability of Doppler measurements were higher: 0.926 (95% CI 0.826-0.970) for peak velocity, 0.922 (95% CI 0.817-0.968) for mean velocity, and 0.868 (95% CI 0.701-0.945) for end-diastolic velocity. Similarly, between-day reproducibility revealed lower values: 0.800 (95% CI 0.567-0.915), 0.786 (95% CI 0.542-0.909), and 0.778 (95% CI 0.527-0.905) respectively. In both cohorts, the intra-observer Bland Altman analysis demonstrated acceptable mean measurement differences and limits of agreement between series of middle cerebral artery velocity measurements with very few outliers. In patients, the carotid stenoses were 30-40% (n = 9), 40-50% (n = 6), 50-70% (n = 3) and > 70% (n = 2). No spontaneous embolisation was detected in either of the groups. Conclusions: Transcranial Doppler generates reproducible data regarding the middle cerebral artery velocities. However, larger studies are needed to validate its clinical applicability.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.0
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据