4.4 Article

Selective detection of monohydroxy metabolites of polycyclic aromatic hydrocarbons in urine using liquid chromatography/triple quadrupole tandem mass spectrometry

期刊

RAPID COMMUNICATIONS IN MASS SPECTROMETRY
卷 18, 期 19, 页码 2299-2308

出版社

WILEY
DOI: 10.1002/rcm.1625

关键词

-

资金

  1. NCI NIH HHS [1R21 CA94743-02] Funding Source: Medline
  2. NIEHS NIH HHS [P30 ES05022] Funding Source: Medline
  3. NATIONAL CANCER INSTITUTE [R21CA094743] Funding Source: NIH RePORTER
  4. NATIONAL INSTITUTE OF ENVIRONMENTAL HEALTH SCIENCES [P30ES005022] Funding Source: NIH RePORTER

向作者/读者索取更多资源

Polycyclic aromatic hydrocarbons (PAHs) are ubiquitously present in the environment and associated with a variety of adverse health effects. Monohydroxylated PAHs (OH-PAHs), metabolites of PAHs, have been employed as biomarkers for human exposure assessment of PAHs. This manuscript describes new, selective detection methods for OH-PAHs using liquid chromatography and tandem mass spectrometry (LC/MS/MS). Electrospray ionization was operated in the negative ion mode to detect the deprotonated PAH metabolites ([M-H](-)). Hydroxylated metabolites of naphthalene, fluorene, phenanthrene, fluoranthene, pyrene, benzo[c]phenanthrene, chrysene, benzo[a]anthracene, and benzo[a]pyrene were selected for the method development. Based on the collision-induced dissociation MS/MS spectra of the selected OH-PAHs, a characteristic ion fragmentation, loss of 28 Da from the [M-H](-) ion, was identified for all of these OH-PAHs. This characteristic fragmentation was exploited for selective screening for OH-PAHs in human urine by incorporating a constant neutral loss (CNL) scan with data-dependent scanning, using a triple quadruple mass spectrometer. Selected reaction monitoring (SRM) was also used to tentatively identify isomers of the target OH-PAHs in human urine. The excellent linearity (3-4 orders of magnitude) and signal-to-noise performance provided by the SRM method allowed development of a sensitive LC/MS/MS method for measuring OH-PAHs in urine samples. The limits of detection of the SRM method ranged from approximately 0.1-5 pg on column for a suite of OH-PAHs tested in the study. The LC-SRM method was applied, following enzymatic deconjugation and solid-phase extraction of the urine, to preliminarily determine the OH-PAH concentrations in urine specimens from six Chinese non-occupationally exposed workers and seven Chinese coke oven workers. Copyright (C) 2004 John Wiley Sons, Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据