4.3 Article Proceedings Paper

Has the 2004 revision of the International Society of Heart and Lung Transplantation grading system improved the reproducibility of the diagnosis and grading of cardiac transplant rejection?

期刊

CARDIOVASCULAR PATHOLOGY
卷 18, 期 4, 页码 198-204

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.carpath.2008.05.003

关键词

Endomyocardial biopsy; Acute cellular rejection; Cardiac transplant rejection; Grading; Interobserver reproducibility; 2004 ISHLT scale

向作者/读者索取更多资源

We compared the interobserver reproducibility of the 1990 and 2004 International Society for Heart and Lung Transplantation (ISHLT) grading system for cardiac rejection. The 2004 ISHLT grading system for cardiac allograft rejection did not improve reproducibility partly due to pathologists' disagreement in diagnosing Grades 1B/1R and 3A/2R rejection. To achieve better reproducibility, better criteria for defining 1B/1R vs. 3A/2R rejection and markers of myocyte injury are needed. (C) 2009 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据