4.6 Article

Modeling the behavior of fiber reinforced polymer-confined concrete columns exposed to fire

期刊

JOURNAL OF COMPOSITES FOR CONSTRUCTION
卷 9, 期 1, 页码 15-24

出版社

ASCE-AMER SOC CIVIL ENGINEERS
DOI: 10.1061/(ASCE)1090-0268(2005)9:1(15)

关键词

concrete columns; fiber reinforced polymers; rehabilitation; confinement; fire resistance; fire protection; heat transfer; numerical analysis

向作者/读者索取更多资源

Very little information is available oil the behavior of fiber reinforced polymer (FRP) materials and FRP-strengthened concrete members in fire, and this is a primary factor hindering the widespread implementation of FRP strengthening technologies in the construction industry. This paper presents a numerical model for evaluating the fire behavior of conventionally reinforced circular concrete columns, FRP-wrapped reinforced concrete columns, and insulated FRP-wrapped reinforced concrete columns. The model is validated against data available in the literature from full-scale fire endurance tests oil conventionally reinforced concrete columns. and preliminary predictions of the model are presented and discussed. It is demonstrated that the model agrees reasonably well with experimental data obtained from tests on circular reinforced concrete columns, that it is unlikely that the structural effectiveness of FRP materials can be maintained during fire, and that the fire behavior of FRP-wrapped columns can be dramatically improved by providing Supplemental insulation for the FRP.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据