4.1 Article

Ochratoxin a content of urine samples of healthy humans in Hungary

期刊

ACTA VETERINARIA HUNGARICA
卷 53, 期 1, 页码 35-44

出版社

AKADEMIAI KIADO ZRT
DOI: 10.1556/AVet.53.2005.1.4

关键词

ochratoxin A; human urine

向作者/读者索取更多资源

The ochratoxin A (OTA) content of urine samples from 88 healthy humans living at five settlements in three counties of Hungary was determined by immunoaffinity column cleanup and high-performance liquid chromatography (HPLC). OTA was detected in 61% of the samples in an average concentration of 0.013 ng/ml (range: 0.006-0.065 ng/ml). OTA concentrations measured in urine samples from men and women were not significantly different. The OTA concentration of samples from Heves county was significantly (t-test; p < 0.003) higher than that of samples from Hajdu-Bihar and Somogy counties. The regional differences in OTA concentration of urine samples indicate regional differences in the OTA exposure of the human population. Further studies are necessary to determine the cause of the regional differences in the OTA intake. The studies allow us to conclude that the OTA intake of the majority of the Hungarian population is low (< 1 ng/kg of body weight per day) but a certain part of the rural population may take up higher levels of OTA.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据