Stimulation of directed bone growth at oxidized titanium implants by macroscopic grooves: An in vivo study

期刊

出版社

WILEY
DOI: 10.1111/j.1708-8208.2005.tb00078.x

关键词

experimental study; histology; removal torque

向作者/读者索取更多资源

Background: The influence of thread design at the millimeter level and surface topography at the micrometer level on bone integration and the stability of dental implants have been studied extensively. However, less is known about the influence of implant structures in the range of 50 to 200 pm. Purpose: The present in vivo investigation was undertaken to study if bone formation and implant stability were influenced by 110 (S 1) and 200 (9) pm-wide and 70 pm-deep grooves positioned at a thread flank of oxidized titanium implants. Materials and Methods: Eighteen rabbits and oxidized titanium implants (3.75 mm in diameter and 7 mm long) were used in the study. Nine rabbits received three control implants and three test implants with a 110 pm-wide groove added to one thread flank. The remaining nine rabbits received three control implants and three test implants with a 200 m-wide groove. The animals were followed for 6 weeks. Removal torque (RTQ) tests were applied to two of the implants in each leg. The remaining implant per leg was retrieved for histology. The degree of bone fill within the grooves and corresponding bone formation at the opposing surfaces, the bone area within the threads, and the degree of bone-implant contact were calculated for each implant. Results: The histologic analyses revealed an affinity for bone formation within the grooves. The RTQ tests showed that the peak RTQ was approximately 30% higher for the S1 implants compared with control implants without a groove. The difference was statistically significant (p <.05) for tibial and pooled implants. A similar but smaller and not statistically significant effect, approximately 8%, was measured for the S3 implants. The histomorphometric measurements confirmed the observed affinity of bone for the grooves. For SI implants, 78.7 +/- 15.8% of the grooves were filled with bone, whereas only 46.2 +/- 27% of the corresponding flank surface showed the presence of bone (p <.05). The corresponding figures for S3 and control implants were 72.7 +/- 25.1% and 48.5 +/- 13.6%, respectively (p <.05). The degrees of bone-implant contact and bone area within the threads were similar for test and control implants. Conclusion: It is concluded that 110 and 200 mu m-wide and 70 mu m-deep grooves at oxidized implant surfaces stimulated bone to preferentially form within and along the groove in the rabbit model. The 110 mu m-wide groove was shown to increase the resistance to shear forces significantly. It is suggested that implants with such a groove may be one way to optimize implant stability in suboptimal clinical conditions.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据