4.4 Article

Development of a liquid chromatography/tandem mass spectrometry method for the quantification of fumonisin B-1, B-2 and B-3 in cornflakes

期刊

RAPID COMMUNICATIONS IN MASS SPECTROMETRY
卷 19, 期 14, 页码 2021-2029

出版社

WILEY
DOI: 10.1002/rcm.2022

关键词

-

向作者/读者索取更多资源

A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of fumonisin B-1 (FB1), B-2 (FB2) and B-3 (FB3) in cornflakes is described. During method development, special attention was paid to the selection of a suitable internal standard (IS) in order to offer a good alternative for deuterated FB1. In this respect, the C-12-Sphinganine analogue (2S,3R)-2-aminododecane-1,3-diol was chosen because of its structural similarity to the fumonisin backbone and its chromatographic elution between the target analytes. For the extraction of the fumonisins from the comflakes matrix, MeOH/H2O (adjusted to pH 4 with 0.1M HCI; 70:30, v/v), ACN/MeOH/H2O (25:25:50, v/v/v) and acidified ACN/MeOH/H2O (25:25:50, v/v/v; pH 4) were evaluated. Preference was given to acidified MeOH/H2O (70:30, v/v) with mean recoveries (n = 12) for FB1, FB2 and FB3 of, respectively, 84 +/- 10, 78 +/- 7 and 85 +/- 9%. Cleanup was performed using immumoaffinity columns (FumoniTest (R), VICAM). The chromatography was performed under isocratic conditions at a flow of 0.3mL min(-1) with a mobile phase consisting of ACN/H2O (60:40, v/v) containing 0.3% formic acid. The mass spectrometer was operated in the positive electrospray ionization (ESI+) mode using multiple reaction monitoring (MRM). An intralaboratory validation was conducted with fortified samples determining limits of detection (LOD), limits of quantification (LOQ), precision, trueness, specificity and measurement uncertainty. The LOD concentrations for FB1, FB2 and FB3 were 20, 7.5 and 12.5 mu g/kg. The LOQs were 40 mu g/kg for FB1, 15 mu g/kg for FB2 and 25 mu g/kg for FB3. The coefficients of variation (CVs) under repeatability conditions varied from 11 to 13% for FB1, from 9 to 14% for FB2 and from 7 to 10% for FB3. Under within-laboratory reproducibility conditions, the CVs ranged from 12 to 17% for FB1, from 9 to 16% for FB2 and from 7 to 13% for FB3. The percent bias for FBI varied from -12 to -10%, while for FB2 and FB3 bias ranged, respectively, from -4 to -2% and from -12 to -5%. The expanded measurement uncertainties for FB1, FB2 and FB3 were, respectively, 19, 18 and 22%. Copyright (c) 2005 John Wiley & Sons, Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据