4.6 Article

Photovoltaic collectors efficiency according to their integration in buildings

期刊

SOLAR ENERGY
卷 80, 期 1, 页码 65-77

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.solener.2005.07.004

关键词

building integrated photovoltaic; simulation tool; environmental life cycle assessment

向作者/读者索取更多资源

A model for building integrated photovoltaic systems has been developed and implemented in a dynamic simulation tool. This tool takes into account the thermal interactions between the PV collector and the building. The influence of the type of integration upon the PV collector efficiency has been evaluated and hybrid PV/air collectors have been studied. An overall efficiency is defined, including the production of electricity and heat. A case study has been performed on two different typical buildings. In the case of a multi-crystalline silicon PV collector integrated on the roof of a single family house located in Paris, the efficiency of unventilated PV modules fixed on the roof is 14%. If the PV collector is used to preheat the ventilation air, the efficiency reaches 20%. A proper building integration also improves the environmental balance of PV technologies over their life cycle. (c) 2005 Elsevier Ltd. All rights reserved.