4.5 Article Proceedings Paper

Estimating the internal conductance to CO2 movement

期刊

FUNCTIONAL PLANT BIOLOGY
卷 33, 期 5, 页码 431-442

出版社

CSIRO PUBLISHING
DOI: 10.1071/FP05298

关键词

internal conductance; mesophyll conductance; photosynthesis; resistance; stomatal conductance; transfer conductance

向作者/读者索取更多资源

The concentration of CO2 in the chloroplast is less than atmospheric owing to a series of gas-phase and liquid-phase resistances. For a long time it was assumed that the concentration of CO2 in the chloroplasts is the same as in the intercellular spaces (e. g. as measured by gas exchange). There is mounting evidence that this assumption is invalid and that CO2 concentrations in the chloroplasts are significantly less than intercellular CO2. It is now generally accepted that internal conductance (g(i)) is a significant limitation to photosynthesis, often as large as that due to stomata. Internal conductance describes this decrease in CO2 concentration between the intercellular spaces and chloroplasts as a function of net photosynthesis [g(i) = A/(C-i - C-c)]. Internal conductance is commonly estimated by simultaneous measurements of gas exchange and chlorophyll a fluorescence or instantaneous discrimination against (CO2)-C-13. These common methods are complemented by three alternative methods based on (a) the difference between intercellular and chloroplastic CO2 photocompensation points, (b) the curvature of an A/C-i curve, and (c) the initial slope of an A/C-i curve v. the estimated initial slope of an A/C-c curve. The theoretical basis and protocols for estimating internal conductance are described. The common methods have poor precision with relative standard deviations commonly > 10%; much less is known of the precision of the three alternative methods. Accuracy of the methods is largely unknown because all methods share some common assumptions and no truly independent and assumption-free method exists. Some assumptions can and should be tested (e.g. the relationship of fluorescence with electron transport). Methods generally require knowledge of either the kinetic parameters of Rubisco, or isotopic fractionation by Rubisco. These parameters are difficult to measure, and thus are generally assumed a priori. For parameters such as these a sensitivity analysis is recommended. One means of improving confidence in gi estimates is by using two or more methods, but it is essential that the methods chosen share as few common assumptions as possible. All methods require accurate and precise measurements of A and C-i - these are best achieved by minimising leaks, maximising the signal-to-noise ratio by using a large leaf area and moderate flow rate, and by taking into account cuticular and boundary layer conductances.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据