4.6 Article

Changes in amplitude-integrated electroencephalography in neonates treated with extracorporeal membrane oxygenation: A pilot study

期刊

JOURNAL OF PEDIATRICS
卷 148, 期 1, 页码 125-127

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.jpeds.2005.07.044

关键词

-

向作者/读者索取更多资源

Neonates (n = 20) treated with extracorporeal membrane oxygenation were evaluated with serial amplitude-integrated electroencephalography (aEEG). There was no acute change in aEEG during extracorporeal membrane oxygenation cannulation, nor were there lateralizing effects. An abnormal aEEG predicted death or moderate to severe intracranial neuropathology,vi sensitivity = 1.0, specificity = 0.75, positive predictive value = 0.86, and negative predictive value = 1.0.