Infection control guidelines for the cardiac catheterization laboratory: Society guidelines revisited

期刊

出版社

WILEY
DOI: 10.1002/ccd.20589

关键词

cardiac catheterization; coronary intervention; adverse effects; quality control; laboratory infection; device infection

向作者/读者索取更多资源

In the early years of diagnostic cardiac catheterization, strict sterile precautions were required for cutdown procedures. Thirteen years ago, when the original guidelines were written, the brachial arteriotomy was still frequently utilized, femoral closure devices were uncommon, implantables, such as intracoronary stents and PFO/ASD closure devices, were in their infancy, and percutaneous valve replacement was not a consideration. In 2005, the cardiac catheterization laboratory is a complex interventional suite with percutaneous access routine and device implantation standard. Despite frequent device implantation, strict sterile precautions are often not observed. Reasons for this include a decline in brachial artery cutdown, limited postprocedure follow-up with few reported infections, limited use of hats and masks in televised cases, and lack of current guidelines. Proper sterile technique has the potential to decrease the patient infection rate. Hand washing remains the most important procedure for preventing infections. Caps, masks, gowns, and gloves help to protect the patient by maintaining a sterile field. Protection of personnel may be accomplished by proper gowning, gloving, and eye wear, disposal of contaminated equipment, and prevention and care of puncture wounds and lacerations. With the potential for acquired disease from blood-borne pathogens, the need for protective measures is as essential in the cardiac catheterization laboratory as is the standard Universal Precautions, which are applied throughout the hospital. All personnel should strongly consider vaccination for hepatitis B. Maintenance of the cardiac catheterization laboratory environment includes appropriate cleaning, limitation of traffic, and adequate ventilation. In an SCAI survey, members recommended an update on guidelines for infection control in the cardiac catheterization laboratory. The following revision of the original 1992 guidelines is written specifically to address the increased utilization of the catheterization laboratory as an interventional suite with device implantation. In this update, infection protection is divided into sections on the patient, the laboratory personnel, and the laboratory environment. Additionally, specific CDC recommendation sections highlight recommendations from other published guidelines. (c) 2005 Wiley-Liss, Inc.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据