期刊
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY
卷 18, 期 6, 页码 1207-1214出版社
SOC BRASILEIRA QUIMICA
DOI: 10.1590/S0103-50532007000600015
关键词
water; chromium; copper; lead; flotation; ETAAS
A method for determination of Cr, Cu and Ph in fresh waters, after flotation separation and preconcentration step, by using electrothermal atomic absorption spectrometry (ETAAS) is presented. The possibility of applying iron(III) hepthyldithiocarbamate, Fe(HpDTC)3, as a collector is studied. The experimental parameters affecting the flotation efficiency by a new collector were optimized. It is ascertained that Cr(HI), Cr(VI), Cu(II) and Pb(II) can be separated simultaneously from matrix by addition of 20 mg Fe(III) and 6 mL 0.1 mol L-1 HpDTC(-) to a test sample of I L at pH 6.5. The preconcentration factor of the method is 40. The applicability of the new proposed procedure was verified by the method of standard additions and by inductively coupled plasma optical emission spectrometry (ICP OES), as an independent comparative method. The limit of detection for Cu by flotation/ETAAS method is 0.015 mu g L-1, for Cr is 0.011 mu g L-1, and for Pb 0.025 mu g L-1. It was found that for low concentrations (from 0.025-0.2 mu gL(-1)) RSD for Cu is 1.5%, for Cr 4.2% and for Pb is 7.8%, while for the higher concentration level (from 0.2-4.5 mu g L-1) RSD for Cu is 1.7%, for Cr 2.8% and for Ph is 3.7%.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据