4.7 Article

A novel integrated MEG and EEG analysis method for dipolar sources

期刊

NEUROIMAGE
卷 37, 期 3, 页码 731-748

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.neuroimage.2007.06.002

关键词

MEG; EEG; integration; conductivity; skull; tangential; radial; median-nerve stimulation; somatosensory evoked field; somatosensory evoked potential; inverse problem

资金

  1. NIBIB NIH HHS [R01-EB00790, R01 EB000790] Funding Source: Medline
  2. NICHD NIH HHS [R01-HD053136, R01 HD053136-08, R01 HD053136] Funding Source: Medline
  3. NINDS NIH HHS [R01-NS44623, R01 NS044623, R01 NS018741, R01-NS18741] Funding Source: Medline
  4. EUNICE KENNEDY SHRIVER NATIONAL INSTITUTE OF CHILD HEALTH &HUMAN DEVELOPMENT [R01HD053136] Funding Source: NIH RePORTER
  5. NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING [R01EB000790] Funding Source: NIH RePORTER
  6. NATIONAL INSTITUTE OF NEUROLOGICAL DISORDERS AND STROKE [R01NS044623, R01NS018741] Funding Source: NIH RePORTER

向作者/读者索取更多资源

The ability of magnetoencephalography (MEG) to accurately localize neuronal currents and obtain tangential components of the source is largely due to MEG's insensitivity to the conductivity profile of the head tissues. However, MEG cannot reliably detect the radial component of the neuronal current. In contrast, the localization accuracy of electroencephalography (EEG) is not as good as MEG, but EEG can detect both the tangential and radial components of the source. In the present study, we investigated the conductivity dependence in a new approach that combines MEG and EEG to accurately obtain, not only the location and tangential components, but also the radial component of the source. In this approach, the source location and tangential components are obtained from MEG alone, and optimal conductivity values of the EEG model are estimated by best-fitting EEG signal, while precisely matching the tangential components of the source in EEG and MEG. Then, the radial components are obtained from EEG using the previously estimated optimal conductivity values. Computer simulations testing this integrated approach demonstrated two main findings. First, there are well-organized optimal combinations of the conductivity values that provide an accurate fit to the combined MEG and EEG data. Second, the radial component, in addition to the location and tangential components, can be obtained with high accuracy without needing to know the precise conductivity profile of the head. We then demonstrated that this new approach performed reliably in an analysis of the 20-ms component from human somatosensory responses elicited by electric median-nerve stimulation. (c) 2007 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据