4.5 Article

Interaction of oxygen concentration and retention of pollutants in vertical flow constructed wetlands for CSO treatment

期刊

WATER SCIENCE AND TECHNOLOGY
卷 56, 期 3, 页码 31-38

出版社

IWA PUBLISHING
DOI: 10.2166/wst.2007.502

关键词

CSO treatment; filter layer; mini sensors; oxygen availability; retention soil filter

向作者/读者索取更多资源

The EU Water Framework. Directive (WFD) calls for a good quality of all water bodies. Retention soil filters (RSF) have been developed to treat discharges from combined sewers systems. RSF have proved over the past 15 years to be the most effective measure to meet the EU WFD standards, especially for small or particularly sensitive receiving waters, which require an enhanced reduction of emissions from combined sewer overflows (CSOs). The paper presents results from laboratory-scale experiments, in which the oxygen measurement in the filter plays a main role. The results show remarkable differences in oxygen concentrations in different filter depths. The highest oxygen consumption takes place in the Upper part of the filter. In the lower part the re-aeration of sewage from the soil air dominates. This indicates that the biological activity is limited to the upper part of the filter. The availability of oxygen in the filter is a sign for degradation of wastewater compounds (ammonium, COD) under certain conditions and already takes place during the filter operation. The removal of ammonium especially cannot be strictly divided into phases of sorption during the loading and oxidation during the dry period any more.