4.5 Article

A comparison of the influence of global functional loads vs. local contact anatomy on articular cartilage thickness at the knee

期刊

JOURNAL OF BIOMECHANICS
卷 40, 期 13, 页码 2961-2966

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.jbiomech.2007.02.005

关键词

cartilage thickness; hertzian contact stress; knee; adduction moment

资金

  1. NATIONAL INSTITUTE OF ARTHRITIS AND MUSCULOSKELETAL AND SKIN DISEASES [R01AR049792] Funding Source: NIH RePORTER
  2. NIAMS NIH HHS [R01 AR 049792-04, R01 AR049792-04, R01 AR049792] Funding Source: Medline

向作者/读者索取更多资源

Cartilage contact geometry, along with joint loading, can play an important role in determining local articular cartilage tissue stress. Thus individual variations in cartilage thickness can be associated with both individual variations in joint loading associated with activities of daily living as well as individual differences in the anatomy of the contacting surfaces of the joint. The purpose of this study was to isolate the relationship between cartilage thickness predicted by individual variations in contact surface geometry based on the radii of the femur and tibia vs. cartilage thickness predicted by individual variations in joint loading. Knee magnetic resonance (MR) images and the peak knee adduction moments during walking were obtained from 11 young healthy male subjects (age 30.5 +/- 5.1 years). The cartilage thicknesses and surface radii of the femoral and tibial cartilage were measured in the weight-bearing regions of the medial and lateral compartments of three-dimensional models from the MR images. The ratio of contact pressure between the medial and lateral compartments was calculated from the radii of tibiofemoral contact surface geometries. The results showed that the medial to lateral pressure ratios were not correlated with the medial to lateral cartilage thickness ratios. However, in general, pressure was higher in the lateral than medial compartments and cartilage was thicker in the lateral than medial compartments. The peak knee adduction moment showed a significant positive linear correlation with medial to lateral thickness ratio in both femur (R-2 = 0.43, P < 0.0 1) and tibia (R-2 = 0.32,P < 0.01). The results of this study suggest that the dynamics of walking is an important factor to describe individual differences in cartilage thickness for normal subjects. (c) 2007 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据