向作者/读者索取更多资源

Low-pass Butterworth digital filters are commonly used in biomechanics-related research. In general, the input signal is filtered in the forward and reverse directions so that a temporal shift in the output signal does not occur. There are times, however, when introducing a specific time delay is an important consideration when modeling a physiological event. Filtering the data in the forward direction only can be used as an efficient method to account for a specific time delay. Specific delays are possible by carefully selecting the filter order and cut-off frequency. The purpose of this paper is to present the analytical formulation of a general solution for the time delay introduced by a low-pass Butterworth digital filter. (c) 2006 Elsevier Ltd. All rights reserved.