This paper describes a fast gas chromatographic/mass spectrometric (GC/MS) screening method for the detection, in urine, of 36 xenobiotics (30 synthetic anabolic steroids, four narcotics, one diuretic and one stimulant) excreted free or as glucuro-conjugates in urine and detectable as trimethylsilyl (TMS) derivatives. These drugs (and/or their urinary metabolites) can be simultaneously extracted by a single liquid/liquid separation step, at alkaline pH, after enzymatic hydrolysis with beta-glucuronidase and then assayed as TMS derivatives by GC/MS using electron ionisation (EI) and single ion monitoring (SIM) acquisition mode. The total time needed for the GC run is less than 8 min. Good reproducibility of the retention times (CV% <1) and the relative abundances of the diagnostic fragment ions (CV% <10) was observed for all target analytes. The sensitivity of the method is sufficient to match the requirements of the World Anti-Doping Agency (WADA) for the accredited laboratories, with limits of detection (LODs) that are lower than the corresponding WADA minimum required performance limits (MRPLs) for all target compounds. Copyright (C) 2007 John Wiley & Sons, Ltd.