4.5 Article Proceedings Paper

Voltammetric determination of metamitron with an electrogenerated molecularly imprinted polymer microsensor

期刊

ELECTROANALYSIS
卷 19, 期 2-3, 页码 356-363

出版社

WILEY-V C H VERLAG GMBH
DOI: 10.1002/elan.200603731

关键词

electrogenerated MIPs; microsensors; triazines; voltammetry

向作者/读者索取更多资源

A molecularly imprinted polymer microsensor was synthesized onto the surface of a carbon fiber microelectrode (CFME) by cyclic voltammetry between -0.1 V and +1.35 V at a scan rate of 50 mV s(-1). The monomers aniline and o-phenylenediamine (o-PD) were electrocopolymerized in the presence of the template (metamitron) in an aqueous medium of 0.1 M H2SO4. In order to obtain a sensor with the highest number of imprinted sites as possible, different experiments related to the polymerization process were carried out. The response of the synthesized microsensor was linear to the metamitron in the range between 10(-6) and 10(-4) with sensitivity of 0.143 nA mu M-1 with good repeatability (< 9% RSD). Employing these experimental conditions, the microsensor was able to distinguish the metamitron from other closely related triazines like metribuzin or isomethiozin.