期刊
MAGNETIC RESONANCE IN MEDICINE
卷 57, 期 1, 页码 201-205出版社
WILEY
DOI: 10.1002/mrm.21087
关键词
sodium MRI; stroke; multiple-quantum; non-human primate; tissue viability
资金
- NINDS NIH HHS [R01 NS 44818] Funding Source: Medline
- NATIONAL INSTITUTE OF NEUROLOGICAL DISORDERS AND STROKE [R01NS044818] Funding Source: NIH RePORTER
Triple quantum (TQ) sodium MRI techniques with clinically acceptable 18-min data acquisition times were demonstrated in vivo in a nonhuman primate model of focal brain ischemia. Focal brain ischemia was induced in four animals using embolization coils to occlude the posterior cerebral artery, and a balloon catheter to occlude the middle cerebral artery. A statistically significant increase (P < 0.001) in the TQ sodium MRI signal intensity in the ischemic hemisphere relative to the contralateral hemisphere was seen at all time points in all four animals. This increased TO sodium MRI signal intensity was demonstrated as early as 0.6 hr after the onset of ischemia. The TQ sodium MRI hyperintensity corresponded to the anatomical location of the ischemic cortex, as indicated by the registration of the TQ imaging data with anatomical proton MRI data. The results demonstrate that early after them onset of ischemia, there was an increase in the TQ signal intensity in the ischemic hemisphere, and a negligible change in the single quantum (SQ) signal intensity.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐