4.4 Article

Effects of alternating current (AC) and direct current (DC) in electrocoagulation process for the removal of iron from water

期刊

CANADIAN JOURNAL OF CHEMICAL ENGINEERING
卷 90, 期 5, 页码 1160-1169

出版社

WILEY
DOI: 10.1002/cjce.20625

关键词

electrocoagulation; alternating; direct current; iron removal; adsorption kinetics; isotherms

向作者/读者索取更多资源

In practice, direct current (DC) is used in an electrocoagulation processes. In this case, an impermeable oxide layer may form on the cathode as well as corrosion formation on the anode due to oxidation. This prevents the effective current transfer between the anode and cathode, so the efficiency of electrocoagulation processes declines. These disadvantages of DC have been diminished by adopting alternating current (AC) in electrocoagulation processes. The main objective of this study is to investigate the effects of AC and DC on the removal of iron from water using zinc as anode and cathode. The results showed that the optimum removal efficiency of 99.6% and 99.1% with the energy consumption of 0.625 and 0.991?kWh?kL-1 was achieved at a current density of 0.06?A?dm-2, at pH of 7.0 using AC and DC, respectively. For both AC and DC, the adsorption of iron was preferably fitting Langmuir adsorption isotherm, the adsorption process follows second order kinetics and the temperature studies showed that adsorption was exothermic and spontaneous in nature. (c) 2011 Canadian Society for Chemical Engineering

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据