4.6 Article

The different response of apparently identical structures: a far-field lesson from the Mirandola 20th May 2012 earthquake

期刊

BULLETIN OF EARTHQUAKE ENGINEERING
卷 12, 期 5, 页码 2481-2493

出版社

SPRINGER
DOI: 10.1007/s10518-013-9505-9

关键词

Soil-structure double resonance; Site effects; Structural analysis; Structural modeling

向作者/读者索取更多资源

Twin structures, that is structures very similar in terms of geometry, materials, mass distribution etc., founded on the same soil and set at very close distance, are rationally expected to have an identical response to earthquakes. When this does not occur, a role is usually played by factors like the interaction with the surrounding structures or by other anomalies hidden behind the apparent similarity. We present the case of two apparently twin towers that showed a very different response to the 2012 Mirandola (Italy) earthquake ground shaking: one remained perfectly intact while the other had a wide set of fractures on secondary walls. This resulted to be the effect of several contributing factors: the stiffness of the two structures, experimentally measured, provided unexpected differences. This reflected into different modal frequencies for the two towers, with the first and second modes of the damaged tower coincident or very close to the soil resonance. The final result was a coupled soil-structure resonance, implying a much higher displacement of one tower compared to the other, under the same input motion. In Italy, insurance against earthquake damage will probably become compulsory in the near future. This case suggests that the specific soil-structure and structure-structure interaction will have to be carefully evaluated since they can critically affect even apparently identical structures.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据