A Gaussian process emulator approach for rapid contaminant characterization with an integrated multizone-CFD model

期刊

BUILDING AND ENVIRONMENT
卷 70, 期 -, 页码 232-244

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.buildenv.2013.08.023

关键词

Bayesian framework; Gaussian process emulator; Multizone models; Integrated Multizone-CFD; CONTAM; Rapid source localization and characterization

资金

  1. Basic Science Research Program through the National Research Foundation of Korea (NRF)
  2. Ministry of Education, Science and Technology [2010-0025484]
  3. KI Project through KAIST Institute for Design of Complex Systems
  4. National Research Foundation of Korea [2010-0025484] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

This paper explores a Gaussian process emulator based approach for rapid Bayesian inference of contaminant source location and characteristics in an indoor environment. In the pre-event detection stage, the proposed approach represents transient contaminant fate and transport as a random function with multivariate Gaussian process prior. Hyper-parameters of the Gaussian process prior are inferred using a set of contaminant fate and transport simulation runs obtained at predefined source locations and characteristics. This paper uses an integrated multizone-CFD model to simulate contaminant fate and transport, Mean of the Gaussian process, conditional on the inferred hyper-parameters, is used as a computationally efficient statistical emulator of the multizone-CFD simulator. In the post event-detection stage, the Bayesian framework is used to infer the source location and characteristics using the contaminant concentration data obtained through a sensor network. The Gaussian process emulator of the contaminant fate and transport is used for Markov Chain Monte Carlo sampling to efficiently explore the posterior distribution of source location and characteristics. Efficacy of the proposed method is demonstrated for a hypothetical contaminant release through multiple sources in a single storey seven room building. The method is found to infer location and characteristics of the multiple sources accurately. The posterior distribution obtained using the proposed method is found to agree closely with the posterior distribution obtained by directly coupling the multizone-CFD simulator with the Markov Chain Monte Carlo sampling. (C) 2013 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据