4.7 Article

Regional performance targets for transparent near-infrared switching electrochromic window glazings

期刊

BUILDING AND ENVIRONMENT
卷 61, 期 -, 页码 160-168

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.buildenv.2012.12.004

关键词

Dynamic windows; Electrochromic glazings; NIR-switching; Performance targets; Solar heat gain

资金

  1. Laboratory Directed Research and Development funding at the Lawrence Berkeley National Laboratory
  2. DOE Early Career Research Program Award
  3. Office of Science, Office of Basic Energy Sciences, of the US Department of Energy
  4. US Department of Energy [DE-ACO2-05CH11231]

向作者/读者索取更多资源

With building heating and cooling accounting for nearly 14% of the national energy consumption, emerging technologies that improve building envelope performance have significant potential to reduce building energy consumption. Actual savings from these technologies will depend heavily upon their performance in diverse climate and operational conditions. In many cases, early-stage research can benefit from detailed investigation in order to develop performance thresholds and identify target markets. One example, a dynamic, highly transparent, near-infrared switching electrochromic (NEC) window glazing, is the focus of this investigation. Like conventional electrochromics, the NEC glazing can dynamically tune its optical properties with a small applied voltage. Consequently, the glazing can block or transmit solar heat to reduce cooling or heating loads, respectively. Unlike conventional electrochromics, NEC glazings remain transparent to visible light, causing no adverse effect to daylighting or building aesthetics. This study utilizes the software COMFEN to simulate a broad range of NEC performance levels, for commercial and residential buildings in 16 climate-representative reference cities. These simulations are the basis for identifying performance levels necessary to compete with existing static technologies. These results indicate that energy savings are strongly influenced by blocking-state performance. Additionally, residential applications have lower performance requirements due to their characteristic internal heat gains. Finally, the most dynamic NEC performance level is simulated in competition with high performing static alternatives. Here heating and cooling energy savings range from 5 to 11 kWh/m(2) yr for commercial and 8-15 kWh/m(2) yr for residential, in many regions on the order of 10%. (C) 2013 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据