Indoor air quality investigations in a naturally ventilated school building located close to an urban roadway in Chennai, India

期刊

BUILDING AND ENVIRONMENT
卷 54, 期 -, 页码 159-167

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.buildenv.2012.01.016

关键词

Carbon monoxide; Meteorology; Occupancy; Particulate matter; School; Traffic

资金

  1. Ministry of Environment and Forests, Government of India, New Delhi
  2. Kendriya Vidyalaya School, CLRI campus, Chennai

向作者/读者索取更多资源

In this study, indoor air quality parameters were investigated in a naturally ventilated school building located near an urban roadway in Chennai. Monitoring was done during the winter (34 days) and summer (26 days) of 2011. The mean value of indoor PM10, PM2.5, PM1 and CO concentrations were found to be 149 +/- 69, 61 +/- 29, 43 +/- 24, 0.10 +/- 0.18 and 95 +/- 61, 32 +/- 16, 18 +/- 9 mu g/m(3), 0.11 +/- 0.14 ppm, respectively for winter and summer seasons. PM data analysis indicated that the indoor PM10 (60% of time) and PM2.5 (27% of time) levels were often exceeding the National Ambient Air Quality Standards (NAAQS). The indoor -outdoor (I/O) ratios of PM10. PM2.5 and PM1 and CO were found to be 2.52 +/- 2.71, 1.44 +/- 0.67, 0.97 +/- 0.18 and 0.51 +/- 0.38, respectively. The high I/O value of PM10 concentration indicates significant contribution from the activities of occupants inside classroom. The low I/O values for finer PM fractions and CO concentrations confirm the vehicular emission contribution from the adjacent road. The influence of classroom occupancy, comfort parameters, outdoor traffic and meteorological parameters on indoor pollutant concentrations were also investigated. Results showed good correlation between PM with comfort and outdoor meteorological parameters. (C) 2012 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据