4.7 Article Proceedings Paper

Experimental study of ventilation effectiveness and air velocity distribution in an aircraft cabin mockup

期刊

BUILDING AND ENVIRONMENT
卷 43, 期 3, 页码 337-343

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.buildenv.2006.02.024

关键词

indoor air quality; local mean age of air; ventilation effectiveness factor; airflow; aircraft cabin

向作者/读者索取更多资源

Ventilation effectiveness in aircraft cabins is a critical factor for minimizing the cross-contamination of airborne pathogens exhaled by the passengers. In this study, a full-scale section of a Boeing 767 aircraft cabin containing thirty five mannequins was used for evaluating the ventilation effectiveness and characterizing the air distribution. Each mannequin was attached with a body heater and an outlet of carbon dioxide to simulate breathing. A set of experiment trials was conducted to measure the local mean age of air and the ventilation effectiveness factor (VEF) at the breathing level of the passengers. Carbon dioxide was used as the trace gas to determine the local mean age of air and the VEF. The air velocity profiles measured using a volumetric particle tracking velocimetry (VPTV) system was used to generate the airflow patterns and investigate the underlying mechanism affecting the local mean age of air and the VEF. In addition, measurements were conducted at different air supply rates to examine its effect on the ventilation performance. (C) 2006 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据