期刊
BRITISH JOURNAL OF OPHTHALMOLOGY
卷 96, 期 11, 页码 1380-1385出版社
BMJ PUBLISHING GROUP
DOI: 10.1136/bjophthalmol-2012-301580
关键词
-
Aims The study was designed to test the clinical application of the grading of lid-parallel conjunctival folds (LIPCOF) as a diagnostic test for dry eye. Methods At 12 centres in 11 countries, 272 eyes of 272 dry eye patients (75 men, 197 women) were examined. Their mean age was 52.7 +/- 16.2 years. The LIPCOF were graded according to the method of Hoh et al. The tear film break-up time (BUT) was measured, and fluorescein staining and the Schirmer 1 test were performed. The subjective symptoms were evaluated by 16 questions. Results The LIPCOF score demonstrated significant positive correlations with age, dry eye disease severity and fluorescein staining (r>0.2, p<0.001), and negative correlations with BUT and results of the Schirmer 1 test (r<-0.2, p<0.001). The LIPCOF score exhibited a significant correlation with the overall subjective symptoms (r=0.250, p<0.001). The sensitivity and specificity of LIPCOF grading for discriminating between normal and dry eyes were best with the cut-off between LIPCOF degrees 1 and 2. Conclusions The displayed medium sensitivity and specificity, and good positive predictive value of the LIPCOF test support the use of LIPCOF grading as a simple, quick and non-invasive dry eye screening tool.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐