4.5 Article

Experimental study on K-joints of concrete-filled steel tubular truss structures

期刊

JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH
卷 107, 期 -, 页码 182-193

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.jcsr.2015.01.023

关键词

Tubular structures; CFST; Truss; Joint; Failure mode; Resistance

资金

  1. National Science Founding of China [50578042, 51008079]
  2. Siberc (Sustainable and Innovative Bridges Engineering Research Center, Fujian Province Universities - China)
  3. RAS (Sardinian Region - Italy)

向作者/读者索取更多资源

The failure modes of K-joints of Concrete Filled Steel Tubular (CFST) truss structures were investigated through laboratory tests. CFST K-joint specimens consisted of a tubular chord filled with concrete and two braces inclined at the same angle with respect to the chord. Their size was chosen of the same scale as that of joints of real tubular structures currently used in bridges. The results were compared with those obtained by testing K-joint specimens of Circular Hollow Section (CHS) truss structures with the same size. Contrary to CHS K-joints, where a chord face failure mode occurred, in CFST K-joints no failure mode with inward deformation of the chord section can occur. Hence, punching shear failure was shown to be the typical failure mode of CFST K-joints, if no brace failure mode occurred before. Resistance of CFST K-joints to punching shear was then compared with the resistance values calculated through the Eurocode 3 and the AWS code formulae on CHS K-joints. The values provided by the former formula were quite close to (although always lower than) the actual resistance to punching shear of CFST K-joints. Finally, the favourable effect on joint resistance due to additional studs welded to the interior surface of the chord tube of CFST K-joint was also investigated. (c) 2015 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据