4.8 Article

A Sensitive Electrochemiluminescence Immunosensor for Celiac Disease Diagnosis Based on Nanoelectrode Ensembles

期刊

ANALYTICAL CHEMISTRY
卷 87, 期 24, 页码 12080-12087

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.5b02801

关键词

-

资金

  1. MIUR (Rome) [PRIN 2010AXENJ8]
  2. Cross-Border Cooperation Italy-Slovenia Program - Strategic Project TRANS2CARE
  3. Erasmus Placement Program
  4. Ministry of Science and Technological Development (Republic of Serbia)
  5. French Foreign Ministry (Bourse d'Excellence Eiffel)

向作者/读者索取更多资源

We report here the design of a novel immunosensor and its application for celiac disease diagnosis, based on an electrogenerated chemiluminescence (ECL) readout, using membrane-templated gold nanoelectrode ensembles (NEEs) as a detection platform. An original sensing strategy is presented by segregating spatially the initial electrochemical reaction and the location of the immobilized biomolecules where ECL is finally emitted. The recognition scaffold is the following: tissue transglutaminase (tTG) is immobilized as a capturing agent on the polycarbonate (PC) surface of the track-etched templating membrane. It captures the target tissue transglutaminase antibody (anti-tTG), and finally allows the immobilization of a streptavidin-modified ruthenium-based ECL label via reaction with a suitable biotinylated secondary antibody. The application of an oxidizing potential in a tri-n-propylamine (TPrA) solution generates an intense and sharp ECL signal, suitable for analytical purposes. Voltammetric and ECL analyses evidenced that the ruthenium complex is not oxidized directly at the surface of the nanoelectrodes; instead ECL is generated following the TPrA oxidation, which produces the TPrA(center dot+) and TPrA(center dot) radicals. With NEEs operating under total overlap diffusion conditions, high local fluxes of these reactive radicals are produced by the nanoelectrodes in the immediate vicinity of the ECL labels, so that they efficiently generate the ECL signal. The radicals can diffuse over short distances and react with the Ru(bpy)(3)(2+) label. In addition, the ECL emission is obtained by applying a potential of 0.88 V versus Ag/AgCl, which is about 0.3 V lower than when ECL is initiated by the electrochemical oxidation of Ru(bpy). The immunosensor provides ECL signals which scale with anti-tTG concentration with a linearity range between 1.5 ng.mL(-1) and 10 mu g.mL(-1) and a detection limit of 0.5 ng.mL(-1). The sensor is finally applied to the analysis of anti-tTG in human serum samples, showing to be suitable to discriminate between healthy and celiac patients.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据