期刊
MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE
卷 14, 期 2, 页码 79-91出版社
ROUTLEDGE JOURNALS, TAYLOR & FRANCIS LTD
DOI: 10.1080/10913671003715524
关键词
frequency; pedometer; filter; acceleration
资金
- FCT [SFRH/BD/23088/2005]
The purpose of this study was to determine the reliability of the Actigraph GT1M (Pensacola, FL, USA) accelerometer activity count and step functions. Fifty GT1M accelerometers were initialized to collect simultaneous acceleration counts and steps data using 15-sec epochs. All reliability testing was completed using a mechanical shaker plate to perform six different test conditions in Experiment 1 and 18 test conditions in Experiment 2. The overall intra-and inter-instrument reliability of the GT1M was CVintra = 2.9% and CVinter = 3.5% for counts and CVintra = 1.1% and CVinter = 1.2% for steps. No batch effects were evident in the 50 GT1Ms. The Actigraph GT1M accelerometer demonstrated good reliability for measuring both counts and steps. However, the ability of the GT1M to consistently detect acceleration at a given acceleration and frequency condition varied widely. Future studies clarifying the filtering limitations and the threshold necessary to detect the occurrence of movement are warranted.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐