4.6 Article

Development of micro-CT protocols for in vivo follow-up of mouse bone architecture without major radiation side effects

期刊

BONE
卷 49, 期 4, 页码 613-622

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.bone.2011.06.031

关键词

In vivo micro-CT; Skeletal system; Bone architecture; Radiation toxicity; Image quality

资金

  1. Fund for Scientific Research-Flanders (FWO) [G.0569.07, G.0500.08]
  2. Molecular Small Animal Imaging Centre (MoSAIC)
  3. IWT SBO [060819]

向作者/读者索取更多资源

In vivo micro-computed tomography (micro-CT) will offer unique information on the time-related changes in bone mass and structure of living mice, provided that radiation-induced side effects are prevented. Lowering the radiation dose, however, inevitably decreases the image quality. In this study we developed and validated a protocol for in vivo micro-CT imaging of mouse bone architecture that retains high quality images but avoids radiation-induced side effects on bone structure and hematological parameters. The left hindlimb of male C57Bl/6 mice was scanned in vivo at 3 consecutive time points, separated each time by a 2-week interval. Two protocols for in vivo micro-CT imaging were evaluated, with pixel sizes of 9 and 18 mu m and administered radiation doses of 434 mGy and 166 mGy per scan, respectively. These radiation doses were found not to influence trabecular or cortical bone architecture in pre-pubertal or adult mice. In addition, there was no evidence for hematological side effects as peripheral blood cell counts and the colony-forming capacity of hematopoietic progenitor cells from bone marrow and spleen were not altered. Although the images obtained with these in vivo micro-CT protocols were more blurred than those obtained with high resolution (5 pm) ex vivo CT imaging, longitudinal follow-up of trabecular bone architecture in an orchidectomy model proved to be feasible using the 9 pm pixel size protocol in combination with a suitable bone segmentation technique (i.e. local thresholding). The image quality of the 18 pm pixel size protocol was too degraded for accurate bone segmentation and the use of this protocol is therefore restricted to monitor marked changes in bone structure such as bone metastatic lesions or fracture healing. In conclusion, we developed two micro-CT protocols which are appropriate for detailed as well as global longitudinal studies of mouse bone architecture and lack noticeable radiation-induced side effects. (C) 2011 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据