Specimen diameter and side artifacts in cancellous bone evaluated using end-constrained elastic tension

期刊

BONE
卷 47, 期 2, 页码 371-377

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.bone.2010.03.024

关键词

Cancellolls bone; Specimen diameter; Elastic modulus; Continuum limit

资金

  1. Natural Sciences and Engineering Research Council of Canada (NSERC)
  2. Ontario Graduate Scholarship (OGS) Program

向作者/读者索取更多资源

In cancellous bone testing of cored samples, side artifacts are the underestimation of the true (i.e. in situ) mechanical properties due to the severing of the trabecular network during specimen preparation. Although other researchers have suggested correction factors derived from finite element method (FEM) models, it is proposed that side effects can be minimized by increasing the specimen diameter. Six different diameter specimens (3.1-10.6 mm), from two different anatomic sites (bovine femoral condyle and bovine lumbar vertebrae), were mechanically tested in elastic tension using an epoxy endcap protocol to eliminate end artifacts. Elastic modulus was found to be significantly affected by diameter in both sites. For example, the 5.1 mm samples underestimated the elastic modulus of the 10.6 mm samples by an average of roughly 20%. Yet no statistical difference was detected between the 8.3 and 10.6 mm samples in either anatomic site, suggesting that 8.3 mm diameter specimens were sufficiently large to avoid side artifacts. FEM models created from micro-CT images reveal that modulus approaches an asymptotic value with increasing diameter, and demonstrate an architecture-dependent drop in modulus at decreasing diameters. These results confirm, both experimentally and numerically, that side effects can be ignored given a suitably large specimen diameter and that this minimum diameter will be dependent on the cancellous architecture. An important implication of the latter result is that specimen diameters must be chosen appropriately when comparing test groups with different architectures (e.g. normal versus osteoporotic) to ensure that the magnitude of side artifacts does not confound the true differences between the groups. (C) 2010 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据