4.6 Article

Magnetic Resonance Imaging of Vascular Oxygenation Changes during Hyperoxia and Carbogen Challenges in the Human Retina

期刊

出版社

ASSOC RESEARCH VISION OPHTHALMOLOGY INC
DOI: 10.1167/iovs.10-6108

关键词

-

资金

  1. Pilot grant
  2. Translational Technology Resource [UL1RR025767]
  3. NIH/NEI [R01 EY014211, EY018855]
  4. Department of Veterans Affairs
  5. NATIONAL CENTER FOR ADVANCING TRANSLATIONAL SCIENCES [UL1TR000149] Funding Source: NIH RePORTER
  6. NATIONAL CENTER FOR RESEARCH RESOURCES [UL1RR025767] Funding Source: NIH RePORTER
  7. NATIONAL EYE INSTITUTE [R01EY014211, R01EY018855, R01EY009702] Funding Source: NIH RePORTER

向作者/读者索取更多资源

PURPOSE. To demonstrate blood oxygenation level-dependent (BOLD) magnetic resonance imaging (MRI) of vascular oxygenation changes in normal, unanesthetized human retinas associated with oxygen and carbogen challenge. METHODS. MRI was performed with a 3-T human scanner and a custom-made surface-coil detector on normal volunteers. BOLD MRI with inversion recovery was used to suppress the vitreous signal. During MRI measurements, volunteers underwent three episodes of air and 100% oxygen or carbogen (5% CO2 and 95% O-2) breathing. Eye movement was effectively managed with eye fixation, synchronized blinks, and postprocessing image coregistration. BOLD time-series images were analyzed using the cross-correlation method. Percent changes due to oxygen or carbogen inhalation versus air were tabulated for whole-retina and different regions of the retina. RESULTS. Robust BOLD responses were detected. BOLD MRI percent change from a large region of interest at the posterior pole of the retina was 5.2 +/- 1.5% (N = 9 trials from five subjects) for oxygen inhalation and 5.2 +/- 1.3% (N = 11 trials from five subjects) for carbogen inhalation. Group-averaged BOLD percent changes were not significantly different between oxygen and carbogen challenges (P > 0.05). The foveal region had greater BOLD response compared with the optic nerve head region for both challenges. CONCLUSIONS. BOLD retinal responses to oxygen and carbogen breathing in unanesthetized humans can be reliably imaged at high spatiotemporal resolution. BOLD MRI has the potential to provide a valuable tool to study retinal physiology and pathophysiology, such as how vascular oxygenation at the tissue level is regulated in the normal retina, and how retinal diseases may affect oxygen response. (Invest Ophthalmol Vis Sci. 2011; 52: 286-291) DOI: 10.1167/iovs.10-6108

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据