4.6 Article

The thyrohyoid membrane as a target for ultrasonography-guided block of the internal branch of the superior laryngeal nerve

期刊

JOURNAL OF CLINICAL ANESTHESIA
卷 27, 期 7, 页码 548-552

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jclinane.2015.07.016

关键词

Airway management; Difficult airway; Nerve block; Superior laryngeal nerve; Ultrasonography

资金

  1. Slovenian Research Agency [P3-043]

向作者/读者索取更多资源

Study objective: The objective was to present a proof of concept for a simple and consistently successful ultrasonograpy (US)-guided technique to block the internal branch of the superior laryngeal nerve (iSLN). Design: This was a volunteer and cadaver anatomy study. Setting: The setting was an anesthesiology department and an anatomy laboratory at a medical school Measurements: H13-6 MHz US scans were performed in 40 healthy volunteers positioned supine and with extended necks. The goals were to identify the thyrohyoid membrane, measure its depth (in centimeters) using the shortest vertical distance from the skin, and record the scanning time (in seconds) needed to obtain the optimal image. Anatomical dissection was performed with an operating microscope bilaterally on 5 adult cadaver heads, fixed in formalin, to expose the point of iSLN penetration through the thyrohyoid membrane. The distance between the greater horn of the hyoid bone and the nerve entry point into the thyrohyoid membrane was measured. Ultrasonography-guided in-plane injections were performed unilaterally with 22-gauge 50-mm nerve block needles in 3 fresh cadavers with 2-mL lidocaine/methylene blue mixture deposited under direct vision just superficial to the thyrohyoid membrane to evaluate technical feasibility and injectate spread. Main results: Anatomically, the iSLN was identified in all formalin-preserved cadavers, with hyoid bone greater horn to nerve-membrane interface distances measuring 1.0-2.4 cm (mean, 2.0 cm; SD, 0.5). Sonographically, the iSLN was not visualized, whereas the hyoid bone and the thyrohyoid membrane were visualized in all volunteers. The mean distance from skin to thyrohyoid membrane was 1.69 cm (SD, 0.38). The mean time needed to scan was 15 seconds (SD, 2.3). After US-guided injection, the dye deposition was observed around the iSLN in all cadaver specimens. Conclusions: A simpler and consistently reproducible US-guided iSLN block is feasible using the thyrohyoid membrane as target plane for local anesthetic injection. Clinical trials are needed to determine its effectiveness and safety, needle entry point, trajectory, and local anesthetic volume. (C) 2015 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据