4.7 Article

Upgrading a wastewater treatment plant with thermophilic digestion of thermally pre-treated secondary sludge: techno-economic and environmental assessment

期刊

JOURNAL OF CLEANER PRODUCTION
卷 102, 期 -, 页码 353-361

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.jclepro.2015.04.051

关键词

Enhanced stabilization process; Thermal hydrolysis; Economic assessment; Life cycle assessment; Mass balance; Technical assessment

资金

  1. European Union [265156]

向作者/读者索取更多资源

Nowadays, several technologies and management strategies are proposed for upgrading wastewater treatment plants (WWTPs) in order to improve sludge stabilization or minimize sludge production. In order to make sure that this leads to overall improvements, their techno-economic and environmental performance has to be carefully evaluated. In response to this, the techno-economic and environmental performance was assessed for a considered model reference WWTP upgraded with separate treatment and disposal for primary and secondary sludge to provide guidance to research, policy and investment efforts. This paper departs in an experimental campaign carried out within the EU project ROUTES and describes an assessment of an upgrade of a WWTP, involving wet oxidation of primary sludge and thermophilic anaerobic digestion (integrated with thermal hydrolysis pre-treatment) for secondary sludge. The reference plant and the upgrade implied different disposal routes for the resulting sludges: incineration for the stabilized sludge deriving from the reference WWTP; agricultural land application for the secondary stabilized sludge from the upgraded plant and landfilling for the solid residue deriving from the wet oxidation process (as non-hazardous waste). The mass balance carried out for both reference and upgraded WWTPs showed a reduction of total sludge production (up to 45%) for the upgraded WWTP. The additional energy demand of the upgraded solution (+22.4 Wh/(PE d), PE: population equivalent) was partially balanced by the electric energy produced by combined heat and power unit installed in the upgraded WWTP (-18.08 Wh/(PE d)). The integrated assessment showed that the upgraded solution, although resulting in an increase of WWTP technical complexity, may contribute to environmental and economic advantages. The paper provides guidance in terms of which aspects need a more thorough evaluation when this upgrade is considered in real cases. (C) 2015 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据