4.6 Article

Fluorescence ELISA based on CAT-regulated fluorescence quenching of CdTe QDs for sensitive detection of FB1

期刊

ANALYTICAL METHODS
卷 10, 期 48, 页码 5797-5802

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/c8ay02065e

关键词

-

资金

  1. National Natural Science Foundation of China [31760485, 31471648]
  2. Major projects of Natural Science Foundation of Jiangxi province [20161ACB20002]
  3. Science Technology Support Program of Jiangxi Province [12003439]
  4. Research Program of the State Key Laboratory of Food Science and Technology, Nanchang University [SKLF-ZZB-201716]

向作者/读者索取更多资源

A competitive fluorescence enzyme-linked immunosorbent assay (cFELISA) was developed for the highly sensitive detection of fumonisin B-1 (FB1) based on the catalase (CAT)-regulated fluorescence quenching of mercaptopropionic acid-modified CdTe quantum dots (MPA-QDs). We propose a system that uses an FB1-labeled CAT (FB1-CAT) as a competing antigen for hydrogen peroxide (H2O2) decomposition, and H2O2-sensitive MPA-QDs were adopted provided the signal output of the cFELISA. Various parameters that could influence the sensitivity of cFELISA, including the labeled molar ratio of FB1 to CAT in FB1-CAT, concentration of the anti-FB1 monoclonal antibodies and FB1-CAT, hydrolysis time of CAT to H2O2, and the pH and methanol concentration in the sample solution, were optimized. The developed cFELISA exhibits a favorable dynamic linear quantitative detection of FB1 over the range of 0.39-12.50 ng mL(-1) under the optimized detection conditions. The half maximal inhibitory concentration and limit of detection were 1.95 and 0.33 ng mL(-1), respectively, which were approximately 10- and 15-fold lower than those of a horseradish peroxidase-based colorimetric ELISA. The recovery of intra- and inter-assays for FB1-spiked corn samples ranged from 80.9% to 87.7% and 85.8% to 93.1%, with a coefficient of variation ranging from 5.5% to 8.6% and 11.5% to 17.4%, respectively. Moreover, the proposed cFELISA exhibited negligible cross-reaction with other common mycotoxins. The reliability of the proposed method was further confirmed by ultra-performance liquid chromatography with fluorescence detection. The proposed method displays remarkable potential for the rapid, sensitive, and cost-effective detection of mycotoxins or analytes with applications in food quality control and safety monitoring.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据