4.6 Article

Contact solid-phase microextraction with uncoated glass and polydimethylsiloxane-coated fibers versus solvent sampling for the determination of hydrocarbons in adhesion secretions of Madagascar hissing cockroaches Gromphadorrhina portentosa (Blattodea) by gas chromatography-mass spectrometry

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1388, 期 -, 页码 24-35

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2015.02.027

关键词

Contact solid-phase microextraction; Glass fiber sampling; Polydimethylsiloxane-fiber sampling; Insect adhesion secretion; In vivo sampling; Alkane pattern

资金

  1. German Research Foundation (DFG) [PAK 478]
  2. Struktur- und Innovationsfonds Baden-Wurttemberg (SI-BW)

向作者/读者索取更多资源

Molecular profiles of adhesion secretions of Gromphadorrhina portentosa (Madagascar hissing cockroach, Blattodea) were investigated by gas chromatography mass spectrometry with particular focus on a comprehensive analysis of linear and branched hydrocarbons. For this purpose, secretions from the tarsi (feet), possibly contributing to adhesion on smooth surfaces, and control samples taken from the tibiae (lower legs), which contain general cuticular hydrocarbons that are supposed to be not involved in the biological adhesion function, were analyzed and their molecular fingerprints compared. A major analytical difficulty in such a study constitutes the representative, spatially controlled, precise and reproducible sampling from a living insect as well as the minute quantities of insect secretions on both tarsi and tibiae. Thus, three different in vivo sampling methods were compared in terms of sampling reproducibility and extraction efficiency by replicate measurement of samples from tarsi and tibiae. While contact solid-phase microextraction (SPME) with a polydimethylsiloxane (PDMS) fiber showed higher peak intensities, a self-made uncoated glass fiber had the best repeatability in contact-SPME sampling. Chromatographic profiles of these two contact-SPME sampling methods were statistically not significantly different. Inter-individual variances were larger than potentially existing minor differences in molecular patterns of distinct sampling methods. Sampling by solvent extraction was time consuming, showed lower sensitivities and was less reproducible. In general, sampling by contact-SPME with a cheap glass fiber turned out to be a viable alternative to PDMS-SPME sampling. Hydrocarbon patterns of the tarsal adhesion secretions were qualitatively similar to those of epicuticular hydrocarbon profiles of the tibiae. However, hydrocarbons were in general less abundant in tarsal secretions than secretions from tibiae. (C) 2015 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据