4.7 Article

Enthalpy-temperature plots to compare calorimetric measurements of phase change materials at different sample scales

期刊

JOURNAL OF ENERGY STORAGE
卷 15, 期 -, 页码 32-38

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.est.2017.11.002

关键词

Thermal energy storage (TES); Latent heat storage; Phase change material (PCM); Storage capacity; Enthalpy curve; T-History

资金

  1. German Federal Ministry for Economic Affairs and Energy [0327851D]
  2. Spanish government [ENE2011-22722, ENE2015-64117-C5-1-R, ULLE10-4E-1305, BES-2012-051861]
  3. Catalan Government [2014 SGR 123]
  4. European Union's Seventh Framework Programme (FP7) [PIRSES-GA-2013-610692]
  5. European Union's Horizon research and innovation programme [657466]
  6. FONDAP SERC-Chile [15110019]
  7. Education Ministry of Chile [PMI ANT 1201]
  8. Ministry of Education of Chile [ANT 1106]
  9. CONICYT/PAI [7813110010]

向作者/读者索取更多资源

Phase change materials (PCM) can provide high thermal energy storage capacities in narrow temperature ranges around their phase change temperature. The expectable maximum storage capacity of a PCM in a defined temperature range is equal to the enthalpy change in that range and can be determined via calorimetric measurements such as differential scanning calorimetry (DSC) or T-History calorimetry. T-History samples (similar to 15 mu l) are about 1000 times larger than DSC samples (similar to 15 ml). Experiments in a pilot plant are performed to study the charging and discharging behaviour of even larger amounts of the PCM (similar to 150 l). The common practise is to investigate PCM at one scale, rarely at two scales. In this work, the characterisation was carried out at three scales (DSC, T-History, and pilot plant) for four PCM (RT58, bischofite, D-mannitol, and hydroquinone). Thereby, the question arises how the enthalpy changes measured at different scales and under different conditions can be compared. In literature, the melting enthalpy is usually assigned to a single temperature without indicating the temperature range considered for evaluation. In very few instances, the enthalpy change within a defined temperature range is stated. In both cases, results measured under different conditions are difficult to compare. In this work, it is demonstrated that enthalpy-temperature plots facilitate the comparison and interpretation of measurements obtained under different experimental methods at different sample scales. (C) 2017 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据