4.8 Article

Aptasensor designed via the stochastic tunneling-basin hopping method for biosensing of vascular endothelial growth factor

期刊

BIOSENSORS & BIOELECTRONICS
卷 119, 期 -, 页码 25-33

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2018.07.073

关键词

Aptasensor; Single-stranded DNA aptamer; VEGF; Stochastic tunneling-basin hopping method; Molecular dynamics simulation

资金

  1. Ministry of Science and Technology of Taiwan [MOST105-2221-E-110-030-MY3, MOST106-2628-E-110-001-MY3, MOST106-2628-B-110-001-MY4]
  2. NSYSU-KMU JOINT RESEARCH PROJECT from Kaohsiung Medical University, Taiwan [NSYSUKMU 107-P032]
  3. Chang Gung Memorial Hospital, Taiwan [CMRPG3E1941-2]

向作者/读者索取更多资源

The Systematic Evolution Ligands by Exponential Enrichment (SELEX) is common used for selection of high affinity single-stranded DNA (ssDNA) aptamer with target protein. However, we do not know what the most stable configuration of the selected aptamer bound with target protein is. Therefore, a systematic search process using the stochastic tunneling-basin hopping (STUN-BH) method is proposed to find the most stable configuration of the ssDNA aptamer specific for vascular endothelial growth factor (VEGF) capture (Apt(VEGF); 5'-TGT GGGGGTGGACGGGCCGGGTAGA-3'). After the most stable configuration was obtained by the STUN-BH method, molecular dynamics (MD) simulation was carried out to investigate the thermal stability of Apt(VEGF)/VEGF at 300 K in both vacuum and water. All molecular simulations were conducted with the large-scale atomic/molecular massively parallel simulator (LAMMPS), and the AMBER99SB force field was used to describe the atomic interactions for the current Apt(VEGF)/VEGF system. The three most stable Apt(VEGF)/VEGF configurations obtained by the STUN-BH method indicated that AptvEGF residues exhibit greater affinity for VEGF surface loop fragments as compared with surface alpha helix and beta sheet fragments. Results indicated that after the first Apt(VEGF) (Apt(VEGF) I) occupies most of the VEGF loop fragment, the second Apt(VEGF) (Apt (VEGF) II) is adsorbed by the rest of the VEGF loop fragment and the VEGF Chain B beta sheet fragment, resulting in a 24.8% reduction in binding strength as compared to that of Apt(VEGF) I. Furthermore, when Apt(VEGF) I and Apt(VEGF) II chains were stably adsorbed by VEGF, the third Apt(VEGF) (Apt(VEGF) III) chain can only partially attach to VEGF, as confirmed by real Apt(VEGF)-VEGF binding experiments. Lastly, we demonstrated that the aptasensor constructed according to MD simulation is highly. sensitive for VEGF with a linear detection range of 10 pg/mL-10 ng/mL.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据