4.8 Article

A cost-effective sandwich electrochemiluminescence immunosensor for ultrasensitive detection of HIV-1 antibody using magnetic molecularly imprinted polymers as capture probes

期刊

BIOSENSORS & BIOELECTRONICS
卷 54, 期 -, 页码 199-206

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2013.10.044

关键词

Sandwich electrochemiluminescence immunosensor; Surface imprinting; Epitope imprinting; Human immunodeficiency virus type 1 antibody; Horseradish peroxidase; Luminol

资金

  1. National Natural Science Foundation of China [30901367]
  2. Natural Science Foundation of Zhejiang [LY13C200017, LY12C20004, LY12B01005]
  3. Science and Technology Project of Zhejiang [2012C23101, 2011C23126]
  4. Natural Science Foundation of Ningbo City [2011B82014, 2013A610241]
  5. K.C. Wong Magna Fund in Ningbo University

向作者/读者索取更多资源

In this report, a rapid and cost-effective sandwich electrochemiluminescence (ECL) immiinosensor was constructed for the ultrasensitive detection of human immunodeficiency virus type 1 antibody (anti-HIV-1) using magnetic molecularly imprinted polymers (MMIPs) as capture probes by combining surface and epitope imprinting techniques and antigen conjugated with horseradish peroxidase (HRP-HIV-1) as labels. First, 3-aminobenzeneboronic acid (APBA) was used as the functional monomer and cross-linking reagent, which was polymerized on the surface of silicate-coated magnetic iron oxide nanoparticles (Fe3O4@SiO2 NPs) in the presence of human immunoglobulin G (HIgG), as the template exhibiting the same Pc region but different Fab region to anti-HIV-1 after the addition of the initiator, ammonium persulfate. This process resulted in grafting a hydrophilic molecularly imprinted polymer (MIP) film on the Fe3O4@SiO2 NPs. Thus, MMIPs, which could be reused after eluting the template, were used to recognize and enrich ultra-trace levels of anti-HIV-1. Subsequently, a novel sandwich ECL immunosensor was formed through the immunoreaction between MMIPs conjugated with varied concentrations of anti-HIV-1 and HRP-HIV-1. By the catalysis of HRP immobilized onto HRP-HIV-1 on the ECL system of Luminol-H2O2, a linear response range of the anti-HIV-1 dilution ratio (standard positive serum) was achieved from 1:20,000 to 1:50, with a detection limit of 1:60,000 (S/N=3). The developed method provides a low-cost, simple, and sensitive way for the early diagnosis of HIV infected patients. (C) 2013 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据