4.8 Article

A novel electrochemiluminescence aptasensor based on in situ generated proline and matrix polyamidoamine dendrimers as coreactants for signal amplication

期刊

BIOSENSORS & BIOELECTRONICS
卷 55, 期 -, 页码 313-317

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2013.12.010

关键词

Electrochemiluminescence (ECL); Coreactant; In situ; Aptasensor; Thrombin (TB)

资金

  1. NNSF of China [21275119, 21075100, 21105081]
  2. State Key Laboratory of Electroanalytical Chemistry [SKLEAC2010009]
  3. Ministry of Education of China [708073]
  4. Natural Science Foundation of Chongqing City [CSTC-2009BA1003, CSTC-2010BB4121, CSTC-2011BA7003]
  5. Specialized Research Fund for the Doctoral Program of Higher Education [20100182110015]
  6. Postgraduate Science and Technology Innovation Program of Southwest China University [KB2010006]

向作者/读者索取更多资源

Here, an ultrasensitive electrochemiluminescence (ECL) aptasensor using in situ generated proline and polyamidoamine (PAMAM) dendrimers as coreactant for bis(2,2'-bipyridy1)(5-amino-1,10-phenanthroline) ruthenium(II) (Ru) was successfully constructed for detection of thrombin (TB). Firstly, PAMAM combined with PtNPs was used as platform to assemble substantial Ru, prolidase (GPDA) and avidin labeled thrombin aptamer (avidin-TBA) to form PAMAM-PtNPs-Ru-GDPA-TBA bioconjugate. With the double aptamer-based sandwich assay, the bioconjugate was successfully modified on the electrode surface. The proposed aptasensor possessed three attractive advantages: PAMAM, as a tertiary amine substance, not only served as a platform to immobilize the PtNPs for further assembling prolidase (GPDA) and avidin-TBA, but also used as a coreactant of Ru to amplify the ECL signal. Furthermore, putting the coreactant and luminescence reagent together onto the electrode surface could effectively shorten the reaction time, improve the efficiency of electron transfer, and enhance the ECL signal. Lastly, the in situ generated coreactant proline for Ru catalyzed by GPDA could rapidly increase the concentration of praline around the electrode surface, which could also greatly amplify the ECL signal. With the several amplification factors mentioned above, the proposed ECL aptasensor showed a wide linear range from 0.01 pmol L-1 to 10 nmol L-1 with the detection limit of 5.0 fmol L-1. The experimental results also indicated that the aptasensor exhibited excellent selectivity, stability and reproducibility. (C) 2013 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据