4.8 Article

Signal amplified strategy based on target-induced strand release coupling cleavage of nicking endonuclease for the ultrasensitive detection of ochratoxin A

期刊

BIOSENSORS & BIOELECTRONICS
卷 39, 期 1, 页码 145-151

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2012.07.005

关键词

Target-induced strand release; Nicking endonuclease; Cleavage; Signal amplification; Ochratoxin A; Chemiluminescence

资金

  1. Scientific and Technical Development Project of Qingdao [09-1-3-45-jch, 12-1-4-3-(18)-jch]
  2. National Natural Science Foundation of China [21005045, 21275085]
  3. Taishan Scholar Program of Shandong Province
  4. Open Project Program of State Key Laboratory of Food Science and Technology, Jiangnan University [SKLF-KF-201112]
  5. Scientific Research Startup Foundation of Qingdao University of Science and Technology for Talents

向作者/读者索取更多资源

In this work, a new signal amplified strategy based on target-induced strand release coupling cleavage of nicking endonuclease for the ultrasensitive detection of ochratoxin A (OTA) is reported. OTA aptamer (DNA1) and OTA aptamer complementary (DNA2) were immobilized onto a magnetic bead (MB). In the presence of OTA, DNA2 was dissociated and released from the MB. The released DNA2 then hybridized with DNA3, which was linked at the 5' terminus of the amplification template and can extend along the template in the presence of Phi 29 DNA polymerase. The formed double-stranded DNA was cleaved by nicking endonuclease Nb.BbvCI and produced a short single-stranded DNA. The cleaved DNA strand generated a new site by Phi 29 DNA polymerase and the process of extension and cleavage was cyclical. Thus, a amount of the short single-stranded DNA were produced. Using DNA and ABEI labeled carboxylic silica nanoparticles chemiluminescence (CL) probe, the short single-stranded DNA could be sensitively detected. The CL intensity (Delta I) versus the concentration of OTA was linear in the range from 1.0 x 10(-12) to 5.0 x 10(-8) g mL(-1). The detection limit was 3.0 x 10(-13) g mL(-1), and the RSD was 3.4% at 1.0 x 10(-10) g mL(-1) (n=7). The developed method has been applied to detect OTA in naturally contaminated wheat samples. Due to its simplicity, sensitivity and no need of specific recognition of aptamer for cleavage, this CL bioassay offers a promising approach for the detection of OTA and other biomolecules. (C) 2012 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据