4.8 Article

Electrochemically synthesized molecularly imprinted polymer of thiophene derivatives for flow-injection analysis determination of adenosine-5′-triphosphate (ATP)

期刊

BIOSENSORS & BIOELECTRONICS
卷 41, 期 -, 页码 634-641

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2012.09.038

关键词

Adenosine-5 '-triphosphate ATP; Molecularly imprinted polymer; Piezoelectric microgravimetry; Capacitive impedometry; Flow-injection analysis

资金

  1. European Regional Development Fund (Project ERDF) [POIG.01.01.02-00-008/08 2007-2013]
  2. Foundation for Polish Science [MPD/2009/1/styp19]
  3. Ministry of Science and Higher Education of Poland [IP2010 031770]
  4. US National Science Foundation [1110942]
  5. Direct For Mathematical & Physical Scien
  6. Division Of Chemistry [1110942] Funding Source: National Science Foundation

向作者/读者索取更多资源

Two selective chemosensors for adenosine-5'-triphosphate (ATP) determination featuring molecularly imprinted polymer (MIP) film recognition units were fabricated. For imprinting, three different thiophene derivatives were used as functional monomers. That is, the uracil substituent of bis(2,2'-bithienyl)methane 2 complementarily H-bond paired the adenine moiety of ATP, the boronic acid substituent of thiophene 3 covalently bound vicinal diols of the ribofuranose moiety, and amide substituents of bis(2,2'-bithienyl)methanes 4 bound to the pyrophosphate moieties. Different binding motifs adopted for the ATP recognition and the structure of the supramolecular pre-polymerization complex were optimized with the DFT computing at the B3LYP/3-21G(*) level. MIP films were prepared by potentiodynamic electropolymerization of this complex with the imprinting factor of 9.47 +/- 0.2. An analytical signal was transduced with a 10-MHz resonator of EQCM and a Pt electrode for the piezoelectric microgravimetry (PM) and capacitive impedometry (Cl) determination of ATP, respectively, under FIA conditions. Analytical properties of the MIP film were unraveled by spectroscopic ellipsometry, XPS, IRRAS, and DPV. The limit of detection was 0.1 and 0.2 mu M for the PM and CI chemosensor, respectively, being an order of magnitude lower than the ATP concentration in biological systems. Moreover, cross-selectivity was demonstrated with the adenosine-5'-diphosphate (ADP) imprinting and ATP discrimination. (C) 2012 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据