4.8 Article

Electrochemical sensor based on molecularly imprinted polymer film via sol-gel technology and multi-walled carbon nanotubes-chitosan functional layer for sensitive determination of quinoxaline-2-carboxylic acid

期刊

BIOSENSORS & BIOELECTRONICS
卷 47, 期 -, 页码 475-481

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2013.03.054

关键词

Electrochemical sensor; Sol-gel molecularly imprinted; MWNTs; Chitosan; Quinoxaline-2-carboxylic acid

资金

  1. National Natural Science Foundation of China [31171683]
  2. Ministry of Science and Technology of China [2012AA101602]
  3. Special Fund for Agroscientific Research in the Public Interest [201203069]
  4. Tianjin Municipal Science and Technology Commission [10SYSYJC28300]
  5. Program for Changjiang Scholars and Innovative Research Team in University [IRT1166]

向作者/读者索取更多资源

Quinoxaline-2-carboxylic acid (QCA) is difficult to measure since only trace levels are present in commercial meat products. In this study, a rapid, sensitive and selective molecularly imprinted electrochemical sensor for QCA determination was successfully constructed by combination of a novel modified glassy carbon electrode (GCE) and differential pulse voltammetry (DPV). The GCE was fabricated via stepwise modification of multi-walled carbon nanotubes (MWNTs)-chitosan (CS) functional composite and a sol-gel molecularly imprinted polymer (MIP) film on the surface. MWNTs-CS composite was used to enhance the electron transfer rate and expand electrode surface area, and consequently amplify QCA reduction electrochemical response. The imprinted mechanism and experimental parameters affecting the performance of MIP film were discussed in detail. The resulting MIP/sol-gel/MWNTs-CS/GCE was characterized using various electrochemical methods involving cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and DPV. The sensor using MIP/sol-gel/MWNTs-CS/GCE as working electrode showed a linear current response to the target QCA concentration in the wide range from 2.0 x 10(-6) to 1.0 x 10(-3) mol L-1 with a low detection limit of 4.4 x 10(-7) mol L-1 (S/N=3). The established sensor with excellent reproductivity and stability was applied to evaluate commercial pork products. At five concentration levels, the recoveries and standard deviations were calculated as 93.5-98.6% and 1.7-33%, respectively, suggesting the proposed sensor is promising for the accurate quantification of QCA at trace levels in meat samples. (C) 2013 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据